Brake test on dc shunt motor pdf merge

Therefore, the supply voltage v and the induced voltage e b i. Brake test is also a method of finding efficiency of dc motors. To determine the load characteristics of dc shunt motor. Jun 02, 2015 brake test it is a direct method and consists of applying a brake to a watercooled pulley mounted on the motor shaft as shown in fig. The main advantages of the swinburnes test are as follows. The positive torque corresponds to the motoring operation. The brake band is fixed with the help of wooden blocks gripping the pulley. The power required to test a large machine is small. Types of dc motors dc motor are of 3 types they are 1. Electric braking dynamic braking of dc motor my tech info. Dc machines can be tested by three different methods namely direct method, indirect method and regenerative method. The fig shows that the dynamic or rheostat braking of a dc shunt motor.

Dc motor principle a machine that converts dc power into mechanical energy is known as dc motor. Generally, this test can be done for the low rated dc machines. And the armature winding is connected to external supply voltage hence it plays the role of current carrying conductor. A shunt dc motor connects the armature and field windings in parallel or shunt.

To determine the efficiency of the given dc shunt motor by conducting load test. This parallel configuration allows independent path of current for field winding and armature. Shunt motor is a special type of dc motor which runs at a constant speed. Experiment 6 shunt dc motor ii objective to study the behavior of a shunt dc motor speed when the field resistance is altered. Learners examine the operation of a dc shunt motor and its characteristics. The armature terminals or supply polarity of a separately excited dc motor or shunt dc motor when running are reversed. Whenever the shunt motor load is increased e b vi a r a and flux reduces as a result drop in the armature resistance and armature reaction. Users manual for installation of biotech biogas plant. O if these values are plotted, the graph representing the variation of speed with torque developed is obtained. A dc shunt motor also known as a shunt wound dc motor is a type of selfexcited dc motor where the field windings are shunted to or are connected in parallel to the armature winding of the motor. When a load is applied to a dc shunt motor, its speed decreases, but the motor is able to self. One end of the rope is fixed to the floor via a spring balance s and a known mass is suspended at the other end. As the constant loss is known the efficiency can be predetermined at any load. Why is the dc series motor rpm higher than the dc shunt.

Consequently, shunt motor will not usually run on a. O from the above two characteristics of dc shunt motor, the torque developed and speed at various armature currents of dc shunt motor may be noted. Notice the shunt coil is identified as a coil of fine wire with many turns that is connected in parallel shunt with the armature. But this mechanical braking has more disadvantages. To find the various parameters such as torque, input power, output power etc. Hence, a dc shunt motor is able to selfregulate its speed, and can be referred to as a constant speed motor. It is often necessary in many applications to stop a running motor rather quickly. Replace the permanent magnet in the stator with an electromagnet. Load test on singlephase transformer and three phase transformers. Load test on dc shunt motor and to find efficiency precautions. The brake test is the one kind of load test on dc shunt motor. There are 3 main types of dc motor that are available.

Calculate the induced voltage, the output power, the efficiency and the torque of the motor if the mechanical and the magnetic losses are 900. Speed control of dc shunt motor with field and armature rheostat control 79 2. Swinburnes test and speed control of dc shunt motor. The shunt winding has a large number of turns so that it has appreciable inductance. A shunt excited dc motors terminal voltage is 500 v.

Because loading will be applied directly on shaft of the motor by means of a belt and pulley arrangement. Test the shunt field continuity by measuring and recording the resistance of the shunt with an ohmmeter. C is applied to a shunt motor, the large inductive reactance of shunt winding will reduce the field current too much. Dc motors although ac motors are used in most of the cases, dc motors have many applications and used for multipurpose applications. To draw the performance characteristics of the given dc shunt motor by conducting load test.

Brake test on dc shunt motor electric motor electrical. A 240v dc shunt dc motor has an armature resistance of 0. In a shunt motor, the field and armature windings are connected in parallel. For the braking operation in dynamic braking, the motor is connected in two ways. Dec 29, 2015 the shunt field windings of a dc shunt motor are made of smaller gauge wire, but they have many more turns than a serieswound dc motor. And the armature winding is connected to external supply voltage hence it. The determination of the efficiency of dc machine is important for the testing of dc machines. Load test on dc shunt motor unicon instruments exporter. What is dynamic braking or rheostatic braking of dc motor. Mar 14, 2016 laboratory explanation of break test on dc shunt motor. Smooth braking of a motor can be achieved by electric braking. Vary the motor load using the electromagnetic brake so that various armature currents are obtained. Thus, this method is an economical and convenient method of testing of dc machines.

Since they are connected in parallel, the armature and field windings are exposed to the same supply voltage. Dc shunt motor armature the parallel combination of two windings is connected across a common dc power supply. The template sidebar with collapsible lists is being considered for merging. Brake test on dc shunt motor free download as word doc. The simple brake test described above can be used for small motors only, because in the case of large motors, it.

The company was incorporated in 1954 and is registered with indiamart. December 29, 2015 by danielle collins leave a comment. These motors are offered in cface models for mounting to our enclosed gear drives, and they are available in 16 20 hp and cover voltage ranges from 115 vac to 460 vac. Scribd is the worlds largest social reading and publishing site. Pdf dynamical analysis of dc shunt motor powered by pv. In a shunt dc motor, the armature and field windings are connected in parallel.

The power that a dc machine receives is called the input and the power it gives out is called the output. Hence the smoothness of mechanical braking is dependent on the surface and physical condition of brakes. In case of dc shunt motors, armature is disconnected from the supply and a rheostat variable resistor is connected across it. Now close switch s1 and slowly increase the voltage supplied to 3phase induction motor using autotransformer until it rotates at the rated speed of dc machine. List of requirementsequipmentexperimental panel system unit w 1.

Electrical machinel dc laboratory manual grietelectrical and. Brake test also called as direct loading test of testing the motor. Same voltage is applied to both shunt winding and armature in this motor. This document was uploaded by user and they confirmed. Iron and friction losses of two machines are made equal i by joining the series. That is the reason behind naming it a dc shunt motor.

In electrical terms, parallel is generally denoted as shunt. A dc motor must have 100% field strength to produce its maximum torque and to keep the armature amperage within proper limits. As such, the field windings and armature are connected in a parallel combination, and in electrical terminology a parallel combination is known as a shunt. The system is modeled and simulated to test its operational. Equivalent circuit parameters are armature resistance ra 110 ohms, field resistance rf 2. Variations of speed can be discussed with the formula n. Circuit diagram load test on dc shunt motor figure 1. One end of the rope is fixed to the floor via a spring balance s and a known mass is suspended at the other. Hence the armature current differs and the speed of a dc shunt motor will continue constant which is shown in the fig dotted line ab. This process is called regenerative braking on hybrid and electric cars. As you know that the construction of any type of dc motor is very similar to a dc generator. This paper discusses the speed and torque control of a shunt dc motor through matlab simulink simulations. Boston gear offers a wide range of odp open drip proof ac motors, including brake motors.

In this method, a brake is applied to a watercooled pulley mounted on the motor shaft as shown in fig. Load test on dc shunt motor offered by unicon instruments, a leading supplier of dc shunt motor in sadar bazar, ambala, haryana. A compoundwound motor has both a series and a shunt field winding, i. The torque speed characteristics separate by excited shunt of the machine under dynamic braking mode is as shown in fig. Eb change in eb for various load currents is small, so may be neglected for the time being.

C of a dc shunt generator and to determine its critical. Feb 07, 2017 variations of speed can be discussed with the formula n. The core losses are 200 w, and the mechanical losses are 240 w at full load. Why is the dc series motor rpm higher than the dc shunt motor. O dc series motor variations of speed can be deduced from the formula n. These terms relate to the type of connection of the field windings with respect to the armature circuit. Dc shunt motor theory quiz questions electrician practice tests. Field test electric motor electric generator scribd. Jul 11, 2019 a dc shunt motor also known as a shunt wound dc motor is a type of selfexcited dc motor where the field windings are shunted to or are connected in parallel to the armature winding of the motor. Its operation is based on the principle that when a current carrying conductor is placed in a. One end of the band is fixed to earth via a spring balance s. E now gets two ways of getting dissipated, one at the wheelbrake. Though there are separate branches for the flow of armature current and field current.

Field rheostat should be kept in the minimum position. As resistance increased, the value of the field current will reduce. Construction and principle of operation of the shunt dc motor. Dynamical analysis is carried out through step changes in the load attached. This type of winding is called shunt winding and the motor shunt dc motor. Working principle from the above circuit diagram, we can conclude that if we want to increase the speed of the shunt motor, we will vary the field resistance. Open circuit characteristic occ of dc shunt generator 2. The dc brakes are operated by a solenoid similar in that is being driven by the momentum of the armature design to the ac solenoid brake fig. Open circuit and short circuit tests on single phase transformer. In electrical terminology, a parallel connection is termed shunt. The dynamical analysis of the dc shunt motor fed by pv generator at different solar. The dc shunt motor is 120vdc with rated speed of 1800 revolutions per minute. In this article we are going to discuss about brake test on d.

Parts and principle of operation of a shunt dc motor. Speed control of dc shunt motor with field and armature. What is a dc shunt motor and its advantage and disadvantage. To interpret the load characteristics of a dc shunt motor.

To study the behavior of a shunt dc motor speed when a series resistor is inserted in the armature circuit. When a current carrying conductor is placed in a magnetic field, it experiences a force. C shunt motor is conducted and its performance curves are drawn. Aug 22, 2018 it is also known as reverse current braking.

The motor now works as a generator, producing the braking torque. Energize the stators electromagnet with the power supply, powered in parallel with the rotor. Determination of performance curves 10 separation of losses in dc shunt motor 11 speed control of dc shunt motor by field and armature control. In the case of a dc motor, the magnetic field is produced by the field winding. Jan 14, 2018 load test on dc shunt motor and to find efficiency precautions. This is also well known that the dc machines can be used as a generator as well as as a motor, their is the difference of operation in both case i. Speed control of dc motor shunt type aim a to study the speed control of dc motor below the normal range by armature resistance control and to plot speed vs armature voltage, characteristic. Dc shunt motor should be started and stopped under no load condition. Dynamic braking or rheostatic braking of dc motor in dynamic braking, a braking resistor rb is connected across the armature as soon as the dc motor is disconnected from the supply mains. The high number of turns allows a strong magnetic field to be generated, but the smaller gauge wires provide a high resistance and limit the current flowing through the shunt coil. In mechanical braking, the motor is stopped owed to the friction amongst the movable parts and brake shoe of the motor. Working principle of dc shunt motor, dc series motor and all other dc motors can be stated as follows. However, to make the stopping faster, brake is applied with the help of rubber brake shoes on the rim of the wheels.

We know that any moving or rotating object acquires kinetic energy. To obtain the performance characteristics of a dc shunt motor by load test. To study the behavior of a shunt dc motor speed when the armature voltage is altered. Even in the manual mode of control the same data whatever is available on the. Reduced field strength will cause high armature currents.

1147 110 257 438 1421 1084 618 375 458 756 897 613 1038 1272 426 1553 73 161 1228 702 907 1261 916 739 463 1251 1301 334 1172 123 783